24-92 Bondings / Inspections

Item Ref
Bondings Flightcontrols 24-92-00-210-024-A

SUBTASK 24-92-00-220-063-B C. Inspection of the Elevator Bonding Leads

(1) During the inspection, if you cannot replace the bonding leads that are broken or damaged, the bonding lead installations that follow are satisfactory:

(a) Bonding lead installed near the elevator tip:

  • If less than 25 percent of its strands are damaged.

(b) And for the other bonding leads installed on the elevator:

  • If only one bonding lead is broken or has more than 25 percent of its strands damaged and the other bonding leads have less than 25 percen of their strands damaged.

(2) Replace all the remaining broken or damaged bonding leads in less than 24 months or 7500 flight hours or 5000 flight cycles (the one that occurs first).

Battery Protect C/Bs

PANEL LOC DESIGNATION FIN
2PB1(BAT-1)
105VU A01 FLT CTL/ELAC1/STBY SPLY 16CE1
105VU B01 FLT CTL/SEC1/STBY SPLY 22CE
105VU C01 ELEC/CSM/G /EV AUTO/SPLY 7XE
105VU D01 ELEC/HOT BUS/701PP SPLY 5PB1
105VU E01 ELEC/HOT BUS/701PP SPLY 12PB1
105VU F01 ELEC/BAT REF/BCL1 9PB1
105VU J01 NAV/STBY/INST/BAT 23FN
2PB2(BAT-2)
105VU A02 FLIGHT CONTROLS/ELAC2/STBY SPLY 16CE2
105VU C02 ADIRS/ADIRU1/28VDC 6FP1
105VU D02 ELEC/HOT BUS/702PP SPLY 5PB2
105VU E02 ELEC/HOT BUS/702PP SPLY 12PB2
105VU F02 ELEC/BAT REF/BCL2 9PB2
105VU G02 ELEC/STAT INV/CNTOR/CTL 14XB
106VU B04 CSM/G /EV/MAN/SPLY 6XE